| L-1011 Air Cycle Machine Temperature Ranges |
In order to program the AC behavior of the L-1011 correctly we will have to go a bit deep on the various parameters in the system. First, lets take a look at the normal temperature ranges we should observe on the ECS Monitor in cruise flight. The numbers in the table below correspond to the numbers in the image above:
- [1] Pack Inlet Bleed Air Temperature ... 160º-200ºC in cruise
- [2] Compressor Discharge Temperature ... 60º-80ºC in cruise (depending on Turbine bypass valve setting)
- [3] Turbine Inlet Temperature ... 15º-20ºC in cruise (will vary with RAM air setting)
- [4] ACM Discharge Temperature ... 15º-20ºC in cruise. The lowest possible ACM discharge temperature is 2ºC
- [5] Hot Air Manifold Output Temperature .... 110ºC
Warning Indicators
- Pack Flow Control Switch OVHT light illuminates when the Compressor Discharge Temperature [2] exceeds 200ºC or when the ACM Discharge [4] temperature exceeds 96ºC.
- DUCT OVHT ... illuminates when the Hot Air Manifold Duct temperature has reached 145ºC. This causes both Hot Air Isolation Valves to close until the temperature falls below 120ºC.
- Hot Air Isolation Switch OVHT ... illuminates when the respective valve has reached 135ºC
There are a number of default valve position values that the system simulator needs to take into account.
Turbine Bypass Indicator - The turbine bypass value is positioned full warm until the RAM AIR louvers have reached the full cool position as indicated on the RAM AIR indicator (9 o'clock on the ground or 1 o'clock position in flight). Once this status has been reached, the turbine bypass valve will now be positioned to hold the required temperature. With the pack turned off, the turbine bypass valve will be set to the 11 o'clock position by default.
RAM Air Indicator - With the Pack turned off the the louvers are automatically set to the 9 o'clock position on the ground and the 1 o'clock position in flight.
![]() |
| Turbine and RAM Positions on Ground. |
![]() |
| Turbine and RAM Positions in Flight. |
In part 4 of this series we are going to start developing a model that will allow us to compute the approximate temperatures and cabin zone temperatures base on the relationships established in normal cruise flight. Again, the idea is the create a systems simulation of the L-1011 air conditioning and pressurization system that is as real-world as feasible for this project.