Simulator Integration Planning: ATA 21 - Air Conditioning and Pressurization (Label Assignments - Part 3)

L-1011 Air Cycle Machine Temperature Ranges

In order to program the AC behavior of the L-1011 correctly we will have to go a bit deep on the various parameters in the system. First, lets take a look at the normal temperature ranges we should observe on the ECS Monitor in cruise flight. The numbers in the table below correspond to the numbers in the image above:

  • [1] Pack Inlet Bleed Air Temperature ... 160º-200ºC in cruise
  • [2] Compressor Discharge Temperature ... 60º-80ºC in cruise (depending on Turbine bypass valve setting)
  • [3] Turbine Inlet Temperature ... 15º-20ºC in cruise (will vary with RAM air setting)
  • [4] ACM Discharge Temperature ... 15º-20ºC in cruise. The lowest possible ACM discharge temperature is 2ºC
  • [5] Hot Air Manifold Output Temperature .... 110ºC
The normal Pack Flow outflow for Pack #2 and #3 is between 2000 and 2500 CFM (#1 has 300-400 less). The spring loaded valves for the Pack Flow Control and the Hot Air Manifold will not open if the duct pressure is below 15 PSI.

Warning Indicators
  • Pack Flow Control Switch OVHT light illuminates when the Compressor Discharge Temperature [2] exceeds 200ºC or when the ACM Discharge [4] temperature exceeds 96ºC.
  • DUCT OVHT ... illuminates when the Hot Air Manifold Duct temperature has reached 145ºC. This causes both Hot Air Isolation Valves to close until the temperature falls below 120ºC.
  • Hot Air Isolation Switch OVHT ... illuminates when the respective valve has reached 135ºC
Valve Position Values

There are a number of default valve position values that the system simulator needs to take into account.

Turbine Bypass Indicator - The turbine bypass value is positioned full warm until the RAM AIR louvers have reached the full cool position as indicated on the RAM AIR indicator (9 o'clock  on the ground or 1 o'clock position in flight). Once this status has been reached, the turbine bypass valve will now be positioned to hold the required temperature. With the pack turned off, the turbine bypass valve will be set to the 11 o'clock position by default.

RAM Air Indicator - With the Pack turned off the the louvers are automatically set to the 9 o'clock position on the ground and the 1 o'clock position in flight.

Turbine and RAM Positions on Ground.

Turbine and RAM Positions in Flight.

In part 4 of this series we are going to start developing a model that will allow us to compute the approximate temperatures and cabin zone temperatures base on the relationships established in normal cruise flight. Again, the idea is the create a systems simulation of the L-1011 air conditioning and pressurization system that is as real-world as feasible for this project. 

Tuesday, January 22, 2013

Simulator Integration Planning: ATA 21 - Air Conditioning and Pressurization (Label Assignments - Part 2)

L-1011 AC Pack

Simulating the L-1011 Air Conditioning and Pressurization for the simulator will be a lot of fun. As you saw in part one of this posting, the basics of the pressurization system for the aircraft is realized in the Laminar Research x-plane simulator. However, the Air Conditioning system is not implemented at all. To make the simulation complete these systems need to be simulated in software as well

The image above shows a single AC PACK for the L-1011, there are 3 of them in the system. Each of them has a number of switch controllers. For simplicity of this blog posting I will only talk through one of the packs (pack 2) but the others work exactly the same way.

So we start from top to bottom:

1. Pack Flow Control Switch

Pack Flow control is a switch light that shows either a FLOW BAR or  OVHT (Overheat). Here are the two elements on the actual panel and in the schematic:




The schematic shows a small [S] next to the valve. This indicates that this valve is spring loaded to shut.  In other words, when pressure is coming from the bleed air system the valve will be pushed open by the pressure and the flow bar will illuminate. When the valve gets too hot (bleed air too hot) the OVHT warning illuminates. So why is it a switch if all it takes to illuminate the bar is pressure on the valve. When the switch is "latched" (in) the valve is in normal operation and does exactly what I just describe. When the switch is unlatched (out), however, the valve is permanently closed and will never open, even with bleed air pressure.

2. Hot Air Switch 

The hot air switch allows for bleed air to be directly fed to the hot air planum. The valve is spring loaded [S] and opens automatically with pressure from the bleed air. When the valve is pushed open, the flow bar will illuminate on the switch. This is the normal operation when the switch is latched. When the switch is unlatched the valve will remain closed even with bleed air pressure. When the switch is unlatched the OFF legend illuminates.






3. Temperature Control 

Bleed air from the pack flow control valve (1) is cooled through a primary and a secondary heat exchanger. The cooling provided by the heat exchangers is controlled by the position of the RAM AIR exhaust doors which determine the flow of ambient outside air across the heat exchangers. This is the primary way of cooling air. Additional cooling is provided as needed by the Air Cycle Machine (ACM).  The ACM is a combination compressor and turbine powered by the bleed air flowing through the pack. When the ACM is working primary air from the primary heat exchanger passes through it and is heated by compression, cooled again by the secondary heat exchanger and the rapidly expanded by the turning for additional cooling.

The amount of cooling provided by the ACM is controlled by the Turbine Bypass Valve.



The system either operates in an automatic or manual mode as selected by the switch-light. Latched (in) the mode is automatic and ram air outlet and turbine bypass are controlled by the planum temperature demand. When unlatched (out) the system is in manual mode and the WARM and COOL momentary switches drive the position logic for TURB BYP and RAM AIR.

4. System Monitoring

There are a number of controls and gauges that allow the monitoring of temperatures in the system. All monitoring happens on the the ECS Monitoring panel:


There are a total of 5 temperature parameters that can be monitored for each AC Pack (controlled by the PACK SELECT switch on the ECS Monitor panel). They are:

  1. Pack Inlet Temperature taken right before the Pack Flow Control Valve
  2. Compressor Discharge Temperature measured before air from the ACM enters the secondary heat exchanger.
  3. Turbine Inlet Temperature measured after the secondary heat exchanger and prior to air entering the turbine 
  4. Air Cycle Machine (ACM) Discharge Temperature is measured after the air leaves the pack and water separator and prior to it being mixed into the Cold Planum. 
  5. Hot Manifold Temperature is taken prior to hot air entering the Hot Air Manifold. 



Lastly, the air flow in Cubic Feet per Minute is displayed on the PACK FLOW meter also on the ECS Monitor Panel.

Software Considerations

All in all the system seem pretty complicated, however, from a software perspective it should not be too bad to model a somewhat lifelike system. Each PACK will be an object with attributes and parameters. The code will not attempt to compute actual air flow or heat exchange but will simply roughly approximate what the system would do under certain ambient air and airspeed conditions.

Ambient outside air at altitude and airspeed we can both get from x-plane as a dataref:

sim/weather/temperature_ambient_c
sim/cockpit2/gauges/indicators/airspeed_kts_pilot


With these two I should be able to develop an approximation of cooling efficiency of the air at altitude and simulate the automatic or manual operation of the ACM systems. As mentioned earlier, many of the spring loaded valves open automatically with bleed air pressure in the system. For bleed air there are also a number of datarefs that will come in handy:

sim/cockpit2/annunciators/bleed_air_off ... for each engine
sim/cockpit/warnings/annunciators/bleed_air_fail ... for each engine




Sunday, January 20, 2013

Simulator Integration Planning: ATA 21 - Air Conditioning and Pressurization


ATA 21 is the Systems chapter for Air Conditioning and Pressurization (a complete listing of ATA chapter numbers can be found here). I decided to work through the simulator system integration according to the ATA chapters and that way everything stays in a somewhat logic order. The upper panel of the flight engineer console on the L-1011 is largely consumed by control and indicator elements for ATA 21 and ATA 36 (which is Pneumatic).

Below are images from the original documentation of the L-1011 simulator created by Singer Link Division in the 1980s.

Environmental Control System (ECS) Monitor Panel (*791/A9)

The simulator implements all component pieces of the ECS monitoring panel.

L-1011 Trainer - ECS Monitoring System (Component Labels)

Implemented Components

Gauges
M10 ... Pack Flow 
M11 ... ECS Temperature
M12 ... Cabin Temperature

Switches
S10 ... Pack Select 
S11 ... ECS Temperature Select 
S12 ... Cabin Zone Temperature Select    

Switch Lights
SDS26 . Cool Air Overboard
SDS27 . Cargo Heat Forward
SDS28 . Cargo Heat Mid
SDS29 . Cargo HEat Aft
SDS30 . Instrument Cooling

Annunciators
DS14 .. Avionic Air Forward
DS15 .. Avionic Air Mid

Cabin Pressurization (*791/A9)

Several of the gauges for the pressurization panel are photo simulations on the original Singer Link Division L-1011 simulator. These instruments will be replaced with the real flight hardware as part of the simulator outfit at the museum. However, several switch and annunciator elements are already fully implemented.

L-1011 Trainer - Pressurization (Component Labels)

Implemented Components

Gauges
M1  ... Forward Outflow Valve 
M2  ... Aft Outflow Valve

Switches
S1  ... Forward Outflow Valve Manual Control 
S2  ... Aft Outflow Valve Manual Control 
S9  ... Cabine Altitude Horn Cutout

Switch Lights
SDS1 .. Forward Outflow Valve Manual/Automatic
SDS2 .. Aft Outflow Valve Manual/Automatic

Annunciators
DS12 .. Forward Safety Valve 
DS13 .. Aft Safety Valve

Cabin Temp Control (*791/A9)

The Cabin Temperature and Engine Bleed Control panels are combined. The lower portion of the panel is the cabin temperature control panel. For the ATA 21 integration we will only cover the lower portion of the panel. 


Implemented Components

Gauges
M4  ... #1 Turbine Bypass Valve Position 
M5  ... #1 RAM AIR Valve Position
M6  ... #2 Turbine Bypass Valve Position 
M7  ... #2 RAM AIR Valve Position
M8  ... #3 Turbine Bypass Valve Position 
M9  ... #3 RAM AIR Valve Position

Switches
S1  ... #1 Valve Cool
S2  ... #1 Valve Warm
S3  ... #2 Valve Cool
S4  ... #2 Valve Warm
S5  ... #3 Valve Cool
S6  ... #3 Valve Warm
S7  ... Area Overheat
S8  ... Area Overheat Test

Switch Lights
SDS10 . #1 Pack Flow Control
SDS11 . #2 Pack Flow Control 
SDS12 . #3 Pack Flow Control
SDS13 . #1 Valve Control Auto and Manual
SDS14 . #2 Valve Control Auto and Manual
SDS15 . #3 Valve Control Auto and Manual
SDS16 . Left Hot Air 
SDS17 . Right Hot Air
SDS18 . Left Isolation Valve
SDS19 . Right Isolation Valve
SDS20 . Ground Cont
SDS21 . Flight Station Open Close
SDS22 . Forward Cabin Open Close
SDS23 . Mid Cabin Open Close
SDS24 . Aft Cabin Open Close
SDS25 . Galley Open Close

Annunciators
DS7 ... Area A Overheat
DS8 ... Area H Overheat
DS9 ... Area B Overheat 
DS10 .. Area C Overheat
DS11 .. Planum Duct Overheat