Primary functions of the Engine Isolation Valve are:
It also allows revers flow during engine start, APU/GND air to reverser switch during engine shutdown.
The engine isolation valve locks closed automatically for; a duct overheat, bleed duct overpressure, excessive flow and will close when the fire handle is pulled. With loss of electrical power the valve is fail save open.
- Shut-Off Valve
- Pressure Regulator
- Check Valve
It also allows revers flow during engine start, APU/GND air to reverser switch during engine shutdown.
The engine isolation valve locks closed automatically for; a duct overheat, bleed duct overpressure, excessive flow and will close when the fire handle is pulled. With loss of electrical power the valve is fail save open.

Under normal operating conditions, isolation valves remain open. It is typically only under certain special circumstances, such as for safety reasons or for system maintenance or repair, that they are closed.